What is Blow-Fill- Seal Technology, Aspects of Aseptics Process in Manufacturing of Sterile Dosage Form

Blow-fill-seal (BFS) technology is an automated process by which containers are formed, filled, and sealed in a continuous operation.
A well-designed BFS system should also normally achieve Class 100 (ISO 5) airborne particle levels. Only personnel who have been qualified and appropriately gowned should enter the classified environment surrounding the BFS machinery.

BLOW-FILL- SEAL TECHNOLOGY

Blow-fill-seal (BFS) technology is an automated process by which containers are formed, filled, and sealed in a continuous operation. This manufacturing technology includes economies in container closure processing and reduced human intervention and is often used for filling and packaging ophthalmics, respiratory care products, and, less frequently, injectables. This appendix discusses some of the critical control points of this technology. Except where otherwise noted below, the aseptic processing standards discussed elsewhere in this document should apply to blow-fill-seal technology.

A. Equipment Design and Air Quality

Most BFS machines operate using the following steps.

• Heat a plastic polymer resin

• Extrude it to form a parison (a tubular form of the hot resin)

• Cut the parison with a high-temperature knife

• Move the parison under the blow-fill needle (mandrel)

• Inflate it to the shape of the mold walls

• Fill the formed container with the liquid product

• Remove the mandrel

• Seal

Throughout this operation, sterile-air is used, for example, to form the parison and inflate it prior to filling. In most operations, the three steps with the greatest potential for exposure to particle contamination and/or surrounding air are those in which (1) the parison is cut, (2) the parison is moved under the blow-fill mandrel, and (3) the mandrel is removed (just prior to sealing).

BFS machinery and its surrounding barriers should be designed to prevent the potential for extraneous contamination. As with any aseptic processing operation, it is critical that product contact surfaces be sterile. A validated steam-in-place cycle, or equivalent process, should be used to sterilize the equipment path through which the product is conveyed. In addition, any other surface that represents a potential contamination risk to the sterile product should be sterile.

The classified environment surrounding BFS machinery should generally meet Class 100,000 (ISO 8), or better, standards, depending on the design of the BFS machinery and the surrounding room. HEPA-filtered or sterile air provided by membrane filters should be used during the steps when sterile products or materials are exposed (e.g., parison formation, container molding or filling steps). Air in the critical area should meet Class 100 (ISO 5) microbiological standards during operations. A well-designed BFS system should also normally achieve Class 100 (ISO 5) airborne particle levels. Only personnel who have been qualified and appropriately gowned should enter the classified environment surrounding the BFS machinery. Refer to Section V of this document for guidance on personnel training, qualification, and monitoring.

BFS equipment design typically calls for use of specialized measures to reduce particle levels that can contaminate the exposed product. In contrast to nonpharmaceutical applications using

BFS machinery, control of air quality (i.e., particles) is critical for sterile drug product manufacture. Particles generated during the plastic extrusion, cutting, and sealing processes should be controlled. Provisions for carefully controlled airflow can protect the product by forcing generated particles outward while preventing any ingress from the adjacent environment. Furthermore, equipment designs that separate the filling zone from the surrounding environment provide additional product protection. Barriers, pressure vacuums, microenvironments, and appropriately directed high velocities of sterile air have been found useful in preventing contamination . Smoke studies and multi-location particle data can provide valuable information when performing qualification studies to assess whether proper particle control dynamics have been achieved throughout the critical area.

In addition to suitable design, it is important to establish an adequate preventative maintenance program. For example, because of its potential to contaminate the sterile drug product, the integrity of the cooling, heating and other utility systems associated with the BFS machine should be maintained and routinely monitored.

B. Validation/Qualification

Advantages of BFS processing are known to include rapid container closure processing and minimized aseptic interventions. However, only a properly functioning process can realize these advantages. We recommend affording special attention to setup, troubleshooting of equipment, and related aseptic personnel procedures. Equipment sterilization, media fills, polymer extrusion/sterilization, product-plastic compatibility, forming and sealing integrity, and unit weight variation are among the key issues to address in validation and qualification studies.

Data gathered during such studies should ensure that BFS containers are sterile and, if used for parenteral drugs, nonpyrogenic. This can generally be achieved by validating that time temperature conditions of the extrusion process are effective against endotoxin or spore challenges in the polymeric material.

The choice of appropriate polymer material for a BFS operation includes assessing if a material is pharmaceutical grade, safe, pure, and passes appropriate criteria  for plastics. Polymer suppliers should be qualified and monitored for raw material quality.

C. Batch Monitoring and Control

Various in-process control parameters (e.g., container weight variation, fill weight, leakers, air pressure) provide information to monitor and facilitate ongoing process control. It is essential to monitor the microbial air quality. Samples should be taken according to a comprehensive sampling plan that provides data representative of the entire filling operation. Continuous monitoring of particles can provide valuable data relative to the control of a blow-fill-seal operation.

Container closure defects can be a major problem in control of a BFS operation. It is critical that the operation be designed and set-up to uniformly manufacture integral units. As a final measure, the inspection of each unit of a batch should include a reliable, sensitive, final pharmaceutical product examination that is capable of identifying defective units (e.g., leakers). Significant defects due to heat or mechanical problems, such as wall thickness, container or closure interface deficiencies, poorly formed closures, or other deviations should be investigated in accordance with CFR 211.100 and 211.192.

We are getting great response from our readers , we are fluded with requests of  lot of other informations, and topics on pharmaceuticals , like Drug interactions , Incompatibility , we promise , one of our author who is teaching post graduates in one of best university in USA will be writting over this blog on his topic of intrest , that is Drug interactions .
Truly it will be great to read him on this platform.

We will be writing about Designig of Aseptic process clean rooms for sterile pharmaceutical dosage forms, in next article ,

So stay in touch with our blog .

Over this website you will get complete knowledge about all pharmaceutical manufacturing process and research and development , good manufacturing practices in pharma    and gmp guidelines , Pharma Quality Assurance, pharmaceutical quality assurance , Pharmaceutical Regulatory Affairs  , Sterile Dosage Form and Aseptic process , Aseptic Techniques , Aseptic Manupulations used in Sterile Dosage Form, Injectable Dosage form manufacturing fda guidelines

We encourage you to Signe up to this website and receive our articles by email strait way in to your INBOX as and when we write a new article over this website.

This website is most favorite Amongst professionals almost all pharmaceutical companies in USA , Pharmaceutical companies in UK , Pharmaceutical companies in Japan , Canada , UAE , Pharma companies in India. This website is pharmaceuticals manufacturers guide .


Posted

in

by

Tags:

Comments

Leave a Reply

Blog at WordPress.com.